HDM97
BM

 

Pressure Reference Meter for the Service and Calibration of Medical Devices

 

Pressure measurement in biomedical applications  
Calibration of blood pressure measuring devices  
    HDM97BM


Innovative Details

Pressure Measurement Provides readings either in mmHg, kPa Bar or PSI.
A special mode allows to measure the pressure drop.

IBP HDM97BM
 
   
As option
a higher accuracy is available, which allows the calibration
of blood pressure measurement devices in accordance with DIN EN 1060.
   
For the c
alibration of blood pressure measurement devices
we offer a calibration set according to EN1060.

For more details please refer to "How to calibrate blood pressure measuring devices?"

Stop Watch  
The stop watch function allows the accurate time measurement
with 100 msec. resolution.
Field Calibration The HDM97Pocket meters can be easily adjusted and calibrated in the field.
The loss of time for calibration and service is minimized.
USB-Interface USB 2.0 - electrically insulated in accordance with ISO 60601-1.
Data exchange with other programs is possible via the USB-Interface. See also Data Acquisition
Registration   Manufactured under certified quality management system in accordance to ISO13485.
   
Technical Data
 
   
Pressure  Reading selectable as mmHg, kPa, Bar or PSI
 
Range: -700 to + 1900 mmHg, 2,5 Bar
Resolution: 0.1 mmHg
Accuracy: 0 ... 300 mmHg ± 1 mmHg
otherwise ± 2 mmHg
  in temperature range 20 to 23 °C
Ceramic sensor fluid resistant

Option H with higher accuracy
Range: -700 to + 1900 mmHg, 2,5 Bar
Resolution: 0.01 mmHg
Accuracy: 0 ... 300 mmHg ± 0.5 mmHg,
301 ... 1000 mmHg ± 1 mmHg
otherwise ± 2 mmHg
  in temperature range 20 to 23 °C
Sensor not fluid resistent
Power Supply Li-Ion-Polymer battery, rechargeable with 5 V DC, 500 mA
External charger:
Input Voltage 100 … 245 V / 50/60 Hz
Output Voltage 5 V DC, 500 mA
Or via USB-Interface from a computer
Operates more than 200 hours with fully charged battery
Dimensions and Weight 165 x 82 x 33 mm - 6.5" x 3.2" x 1.3”
0.4 Kg - 0.88 lbs including probe